Home | Site Map | Contact us | Ελληνικά | 

Midea Ceiling Cassette Super Slim MCD1-48HRFNX, 48.000BTU


Midea Ceiling Cassette Super Slim MCD1-48HRFNX, 48.000BTU

 

MIDEA MCD1-48HRFNX-QRD0W 380V CASSETTE 


The Midea MCD1-48HRFNX-QRD0W three-phase cassette type inverter air conditioner has a high energy rating A++ in cooling mode and A+ in heating mode, respectively 6.10 SEER for cooling and 4.00 SCOP for heating. The air conditioner has 360° airflow. It is this feature that allows even distribution of air conditioning throughout the room, and the air conditioning system has a built-in powerful condensate pump. Thanks to the remote control, the shutters of the indoor unit can be controlled individually. The air conditioner has a wide temperature range and operates at extremely low temperatures of -15 ℃

 

FEATURES AND EXTRAS OF THE MIDEA MCD1-48HRFNX-QRD0W THREE-PHASE CASSETTE TYPE INVERTER AIR CONDITIONER


Automatic restart
In the event that the air conditioner stops working unexpectedly due to a power outage, it will restart automatically as soon as power is restored and will start operating in the mode set before the power was turned off.

8°C heating
In 8°C heating mode, this constant temperature is maintained, thus protecting the home from excessive cooling in winter or freezing of pipes and houseplants. The regime is especially suitable in the long absence of the occupants of the home.

Fresh air inlet
Outside air can be supplied through an additional ventilation duct. This ensures clean and fresh air in the air-conditioned room.

360° Airflow
The mode provides extremely light and soft airflow, which circulates throughout the room and ensures even temperature distribution.

Human activity sensor (optional)
The human activity sensor monitors the presence of people in the room and takes into account the power output of the system to ensure perfect comfort.

Emergency operation
In the best air conditioners, when a sensor temperature error occurs, the system stops working. With Midea, the indoor unit reports an error code, but the system continues to operate in emergency mode.

Built-in condensate pump
The built-in condensate pump allows the condensate to rise to a maximum of 750 mm.

Alarm system port
When a fault is detected in the air conditioning system, an external alarm system is activated, which signals an error and automatically stops its operation.

Louver memory
The position of the horizontal valve of the air conditioning system is saved when switched off and is restored automatically when switched on again.

Refrigerant leak detection
The indoor unit of the air conditioner detects an error code ""EC"", which will be displayed and will stop working automatically when a freon leak is detected. This will protect the air conditioning compressor from damage caused by high temperatures when the refrigerant leaks.

Wired Control (optional)
Wired controller can be fixed to the wall for a permanently mounted control solution.

Central Management (optional)
The central control is a multifunctional device that can control up to 64 indoor units with a maximum connection length of up to 1200 meters.

Breezeless
The innovative Breezeless effect ensures even air distribution, thus avoiding direct exposure to people in the room. This eliminates the feeling of airflow from the air conditioning system.

Wi-Fi Ready
The air conditioners of this series have the ability to install a Wi-Fi module that allows the air conditioner to be controlled from anywhere and at any time through a mobile application installed on your smartphone or tablet.

LED display
The indoor unit has a large LED display giving information about the operation of the air conditioning system.

 

TECHNICAL SPECIFICATION FOR MIDEA MCD1-48HRFNX-QRD0W


Model Indoor Unit MCD1-48HRFNX-QRD0W
Outdoor Unit MOE30U-48HFN8-RRD0W
Power Supply V/O/Hz 380-415 / 3 / 50
Capacity Cooling kW 14.07 (3.52 - 15.83)
Heating 16.12 (4.10 - 17.29)
Power Input Cooling / Heating kW 4.65 (0.80 - 5.90) / 4.58 (0.90 - 5.50)
SEER Cooling W/W 6.1
SCOP Heating 4
Energy Efficiency Class Cooling A++
Heating A+
Running Current Cooling/ Heating A 8.10 (1.80 - 10.20) / 8.00 (1.90 - 9.50)
Air Flow (indoor unit) m3/h 1970 / 1780 / 1580
Sound Pressure (indoor unit) dB(A) 51 / 48.5 / 46.5 / 37.5
Sound Power (indoor unit) dB(A) 66
Air Flow (outdoor unit) m3/h 7500
Sound Pressure (outdoor unit) dB(A) 63.5
Sound Power (outdoor unit) dB(A) 74
Dimensions W x D x H
Weight Indoor Unit mm 830 x 830 x 287
kg 29.3
Outdoor Unit mm 952 x 415 x 1333
kg 103.7
Refrigerant piping (liquid/gas) mm 9.52 / 15.9
Max. refrigerant pipe length m 75
Max. difference in level 30
Operation Temperature Cooling °C -15 ~ 50
Heating -15 ~ 24
Refrigerant R32

 

 




There are 0 products in your cart

Quantity:





Members' login
New member
Contact TEPSE
General Catalogue
Mailing list for Tepse news!

Wish to receive our product news and other? Please enter your e-mail address here.

Copyright TEPSE 2010 Home | Site Map | Contact us | Ελληνικά | 
Θα μας βρείτε:
1st Branch: 5 St. Tatti st. P.C. 54622
(Ag. sofias area) Thessaloniki - Greece
t. +30 2310 236321, +30 2310 267168
f. +30 2310 281007
2nd Branch: 6th Klm. Lagkada road (Towards Oreokastro)
P.O. Box 40052 Thessaloniki - Greece
t. +30 2310 681123, +30 2310 685510, 2310 685511
f. +30 2310 684701

active³ 5.3 · IPS κατασκευή E-shop · Disclaimer